1
Fork 0
mirror of git://git.sv.gnu.org/emacs.git synced 2026-01-23 04:53:12 -08:00
emacs/mps/code/protsgix.c
Peter Jackson 1d00afac81 Publish licence updates in code directory.
Publish minor changes to readme and configure files in main directory.
Main directory and code directory licence texts are now fully updated.

Copied from Perforce
 Change: 196994
2020-06-11 17:05:40 +01:00

172 lines
5.9 KiB
C

/* protsgix.c: PROTECTION (SIGNAL HANDLER) FOR POSIX
*
* $Id$
* Copyright (c) 2001-2020 Ravenbrook Limited. See end of file for license.
*
* This implements protection exception handling using POSIX signals.
* It is designed to run on any POSIX-compliant Unix.
*
*
* SOURCES
*
* .source.posix: POSIX specifications for signal.h and sigaction
* <https://pubs.opengroup.org/onlinepubs/9699919799/basedefs/signal.h.html>
* <https://pubs.opengroup.org/onlinepubs/9699919799/functions/sigaction.html>
*
* .source.man: sigaction(2): FreeBSD System Calls Manual.
*
* .source.merge: A blend from primarily the FreeBSD version (protfri3.c)
* and the OSF/1 (DIGITAL UNIX) version (proto1.c); influenced by other
* Unix versions.
*/
#include "mpm.h"
#if !defined(MPS_OS_FR) && !defined(MPS_OS_LI)
#error "protsgix.c is specific to MPS_OS_FR or MPS_OS_LI"
#endif
#include "prmcix.h"
#include <signal.h> /* for many functions */
#include <ucontext.h> /* for ucontext_t */
#include <unistd.h> /* for getpid */
SRCID(protsgix, "$Id$");
/* The previously-installed signal action, as returned by */
/* sigaction(3). See ProtSetup. */
static struct sigaction sigNext;
/* sigHandle -- protection signal handler
*
* This is the signal handler installed by ProtSetup to deal with
* protection faults. It is installed on the signal given by the
* PROT_SIGNAL macro (that is, SIGSEGV). It constructs a mutator
* context based on the signal context, and passes it to ArenaAccess,
* which attempts to handle the fault and remove its cause. If the
* fault is handled, then the handler returns and execution resumes.
* If it isn't handled, then sigHandle does its best to pass the
* signal on to the previously installed signal handler (sigNext);
* which it does by signalling itself using kill(2).
*
* .sigh.args: We set the SA_SIGINFO flag in the sa_flags field of the
* sigaction structure, and so the signal handler in the sa_sigaction
* field receives three arguments: signal number, pointer to signal
* info structure, pointer to signal context structure.
*
* .sigh.check: We check that info->si_code is SEGV_ACCERR (meaning
* "Invalid permissions for mapped object").
*
* .sign.addr: If so, we assume info->si_addr is the fault address.
*
* .sigh.mode: The fault type (read/write) does not appear to be
* available to the signal handler (see mail archive).
*/
#define PROT_SIGNAL SIGSEGV
static void sigHandle(int sig, siginfo_t *info, void *uap) /* .sigh.args */
{
int e;
/* sigset renamed to asigset due to clash with global on Darwin. */
sigset_t asigset, oldset;
struct sigaction sa;
AVER(sig == PROT_SIGNAL);
if(info->si_code == SEGV_ACCERR) { /* .sigh.check */
AccessSet mode;
Addr base;
MutatorContextStruct context;
MutatorContextInitFault(&context, info, (ucontext_t *)uap);
mode = AccessREAD | AccessWRITE; /* .sigh.mode */
/* We assume that the access is for one word at the address. */
base = (Addr)info->si_addr; /* .sigh.addr */
/* Offer each protection structure the opportunity to handle the */
/* exception. If it succeeds, then allow the mutator to continue. */
if(ArenaAccess(base, mode, &context))
return;
}
/* The exception was not handled by any known protection structure, */
/* so throw it to the previously installed handler. That handler won't */
/* get an accurate context (the MPS would fail if it were the second in */
/* line) but it's the best we can do. */
e = sigaction(PROT_SIGNAL, &sigNext, &sa);
AVER(e == 0);
sigemptyset(&asigset);
sigaddset(&asigset, PROT_SIGNAL);
e = sigprocmask(SIG_UNBLOCK, &asigset, &oldset);
AVER(e == 0);
kill(getpid(), PROT_SIGNAL);
e = sigprocmask(SIG_SETMASK, &oldset, NULL);
AVER(e == 0);
e = sigaction(PROT_SIGNAL, &sa, NULL);
AVER(e == 0);
}
/* ProtSetup -- global protection setup
*
* Under Unix, the global setup involves installing a signal handler
* on PROT_SIGNAL to catch and handle page faults (see sigHandle).
* The previous handler is recorded so that it can be reached from
* sigHandle if it fails to handle the fault.
*
* NOTE: There are problems with this approach:
* 1. we can't honor the sa_flags for the previous handler,
* 2. what if this thread is suspended just after calling signal(3)?
* The sigNext variable will never be initialized!
*/
void ProtSetup(void)
{
struct sigaction sa;
int result;
sa.sa_sigaction = sigHandle;
sigemptyset(&sa.sa_mask);
sa.sa_flags = SA_SIGINFO;
result = sigaction(PROT_SIGNAL, &sa, &sigNext);
AVER(result == 0);
}
/* C. COPYRIGHT AND LICENSE
*
* Copyright (C) 2001-2020 Ravenbrook Limited <http://www.ravenbrook.com/>.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions are
* met:
*
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
*
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the
* distribution.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS
* IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED
* TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
* PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
* HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
* SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
* LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
* OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
*/